| B25062 |
| Base SAS 9.21_M3 |
| Issue(s) Addressed: | Introduced: |
| 39517 | "Read Access Violation" or "Segmentation Violation" errors might be generated when creating ODS RTF output |
B25008 |
| 12601 | ODS PRINTER generates "out of memory" errors |
B25062 |
| 38109 | Justification, font, color, and height specifications do not replay to non-Listing ODS destinations when using PROC DOCUMENT |
B25062 |
| 40140 | URLs generated on the mainframe when you use the ODS HTML or the ODS TAGSETS.MVSHTML destination are incorrect in SASŪ 9.2 |
B25062 |
| 41024 | Row headings might overwrite in PROC TABULATE output with ODS PRINTER (PCL/PDF/PS) destinations |
B25062 |
| 41445 | Memory issues might occur when more than 19 DEFINE statements contain style options in PROC REPORT |
B25062 |
NOTE: If you install this hot fix, you must also install Base SAS hot fix B25183.
NOTE: This hot fix is available for OpenVMS on HP Integrity and z/OS. Customers running on all other platforms should install hot fix B25106 instead. |
|
|
| B25088 |
| Base SAS 9.21_M3 |
| Issue(s) Addressed: | Introduced: |
| 39614 | "ERROR: No email addresses specified" when sending email from SASŪ using SMTP |
B25003 |
| 40143 | E-mail output from SASŪ 9.2 fails when attachments have an LRECL value greater than 1000 |
B25027 |
| 40178 | The sender header field is truncated when you use SASŪ software for SMTP e-mail |
B25027 |
| 40978 | The subject lines for e-mails sent from SASŪ might get truncated in some e-mail clients |
B25047 |
| 41926 | ERROR: "Email: The connection was reset by a peer" |
B25088 |
| z/OS |
Released: February 17, 2011 | | Documentation: B25088os.html | | Download: B25088os.bin |
| Windows |
Released: February 17, 2011 | | Documentation: B25088wn.html | | Download: B25088wn.exe |
| Windows for IPF |
Released: February 17, 2011 | | Documentation: B25088w6.html | | Download: B25088w6.exe |
| Windows for x64 |
Released: February 17, 2011 | | Documentation: B25088x6.html | | Download: B25088x6.exe |
| 64-bit Enabled HP-UX |
Released: February 17, 2011 | | Documentation: B25088h6.html | | Download: B25088h6.bin |
| 64-bit Enabled Solaris |
Released: February 17, 2011 | | Documentation: B25088s6.html | | Download: B25088s6.bin |
| 64-bit Enabled AIX |
Released: February 17, 2011 | | Documentation: B25088r6.html | | Download: B25088r6.bin |
| Linux |
Released: February 17, 2011 | | Documentation: B25088lx.html | | Download: B25088lx.bin |
| HP-UX IPF |
Released: February 17, 2011 | | Documentation: B25088hx.html | | Download: B25088hx.bin |
| Linux for x64 |
Released: February 17, 2011 | | Documentation: B25088la.html | | Download: B25088la.bin |
| Solaris for x64 |
Released: February 17, 2011 | | Documentation: B25088sx.html | | Download: B25088sx.bin |
| OpenVMS on HP Integrity |
Released: February 17, 2011 | | Documentation: B25088vi.html | | Download: B25088vi.exe |
|
| B25106 |
| Base SAS 9.21_M3 |
| Issue(s) Addressed: | Introduced: |
| 39517 | "Read Access Violation" or "Segmentation Violation" errors might be generated when creating ODS RTF output |
B25008 |
| 12601 | ODS PRINTER generates "out of memory" errors |
B25062 |
| 38109 | Justification, font, color, and height specifications do not replay to non-Listing ODS destinations when using PROC DOCUMENT |
B25062 |
| 40140 | URLs generated on the mainframe when you use the ODS HTML or the ODS TAGSETS.MVSHTML destination are incorrect in SASŪ 9.2 |
B25062 |
| 41024 | Row headings might overwrite in PROC TABULATE output with ODS PRINTER (PCL/PDF/PS) destinations |
B25062 |
| 41445 | Memory issues might occur when more than 19 DEFINE statements contain style options in PROC REPORT |
B25062 |
| 42238 | Reports generated with SASŪ Enterprise Guide or the SASŪ Add-in for Microsoft Office with DBCS data might contain spaces in labels or cell values |
B25106 |
NOTE: If you install this hot fix, you must also install hot fixes B25183 and B25107 for Base SAS 9.21_M3.
|
| Windows |
Released: April 01, 2011 | | Documentation: B25106wn.html | | Download: B25106wn.exe |
| Windows for IPF |
Released: April 01, 2011 | | Documentation: B25106w6.html | | Download: B25106w6.exe |
| Windows for x64 |
Released: April 01, 2011 | | Documentation: B25106x6.html | | Download: B25106x6.exe |
| 64-bit Enabled HP-UX |
Released: April 01, 2011 | | Documentation: B25106h6.html | | Download: B25106h6.bin |
| 64-bit Enabled Solaris |
Released: April 01, 2011 | | Documentation: B25106s6.html | | Download: B25106s6.bin |
| 64-bit Enabled AIX |
Released: April 01, 2011 | | Documentation: B25106r6.html | | Download: B25106r6.bin |
| Linux |
Released: April 01, 2011 | | Documentation: B25106lx.html | | Download: B25106lx.bin |
| HP-UX IPF |
Released: April 01, 2011 | | Documentation: B25106hx.html | | Download: B25106hx.bin |
| Linux for x64 |
Released: April 01, 2011 | | Documentation: B25106la.html | | Download: B25106la.bin |
| Solaris for x64 |
Released: April 01, 2011 | | Documentation: B25106sx.html | | Download: B25106sx.bin |
|
| B25111 |
| Base SAS 9.21_M3 |
| Issue(s) Addressed: | Introduced: |
| 40494 * | ALERT - A SAS/SHAREŪ server fails or does not respond when it is run as a Microsoft Windows service |
B25041 |
| 41738 | Sporadic abends of the SASŪ Metadata Server occur during start-up |
B25076 |
| 41921 | ERROR: ORACLE connection error: ORA-01017: invalid username/password; logon denied. |
B25076 |
| 42095 * | Attempt to log on to SASŪ Metadata Server fails if a userid containing a DBCS character was used previously |
B25085 |
| 42456 * | You cannot access files on a SAS/SHAREŪ server |
B25095 |
| 41220 * | Mixed-case passwords that are submitted to a SASŪ server in a z/OS operating environment return a security verification failure to the client |
B25111 |
| * Indicates that the fix for the issue described in this SAS Note does not apply to all Operating Systems. |
| z/OS * |
Released: April 28, 2011 | | Documentation: B25111os.html | | Download: B25111os.bin |
| Windows |
Released: April 28, 2011 | | Documentation: B25111wn.html | | Download: B25111wn.exe |
| Windows for IPF |
Released: April 28, 2011 | | Documentation: B25111w6.html | | Download: B25111w6.exe |
| Windows for x64 |
Released: April 28, 2011 | | Documentation: B25111x6.html | | Download: B25111x6.exe |
| 64-bit Enabled HP-UX |
Released: April 28, 2011 | | Documentation: B25111h6.html | | Download: B25111h6.bin |
| 64-bit Enabled Solaris |
Released: April 28, 2011 | | Documentation: B25111s6.html | | Download: B25111s6.bin |
| 64-bit Enabled AIX |
Released: April 28, 2011 | | Documentation: B25111r6.html | | Download: B25111r6.bin |
| Linux |
Released: April 28, 2011 | | Documentation: B25111lx.html | | Download: B25111lx.bin |
| HP-UX IPF |
Released: April 28, 2011 | | Documentation: B25111hx.html | | Download: B25111hx.bin |
| Linux for x64 |
Released: April 28, 2011 | | Documentation: B25111la.html | | Download: B25111la.bin |
| Solaris for x64 |
Released: April 28, 2011 | | Documentation: B25111sx.html | | Download: B25111sx.bin |
| OpenVMS on HP Integrity |
Released: April 28, 2011 | | Documentation: B25111vi.html | | Download: B25111vi.exe |
|
| * z/OS: You must also install hot fix B25193 to fully implement the fix for the issue described in 41220 . |
| B25152 |
| Base SAS 9.21_M3 |
| Issue(s) Addressed: | Introduced: |
| 41574 | Double-byte character sets (DBCS) might not display properly in the ARM log |
B25082 |
| 43854 | ARM4 "Segmentation Violation" error |
B25152 |
| z/OS |
Released: August 12, 2011 | | Documentation: B25152os.html | | Download: B25152os.bin |
| Windows * |
Released: August 12, 2011 | | Documentation: B25152wn.html | | Download: B25152wn.exe |
| Windows for IPF * |
Released: August 12, 2011 | | Documentation: B25152w6.html | | Download: B25152w6.exe |
| Windows for x64 * |
Released: August 12, 2011 | | Documentation: B25152x6.html | | Download: B25152x6.exe |
| 64-bit Enabled HP-UX * |
Released: August 12, 2011 | | Documentation: B25152h6.html | | Download: B25152h6.bin |
| 64-bit Enabled Solaris * |
Released: August 12, 2011 | | Documentation: B25152s6.html | | Download: B25152s6.bin |
| 64-bit Enabled AIX * |
Released: August 12, 2011 | | Documentation: B25152r6.html | | Download: B25152r6.bin |
| Linux * |
Released: August 12, 2011 | | Documentation: B25152lx.html | | Download: B25152lx.bin |
| HP-UX IPF * |
Released: August 12, 2011 | | Documentation: B25152hx.html | | Download: B25152hx.bin |
| Linux for x64 * |
Released: August 12, 2011 | | Documentation: B25152la.html | | Download: B25152la.bin |
| Solaris for x64 * |
Released: August 12, 2011 | | Documentation: B25152sx.html | | Download: B25152sx.bin |
| OpenVMS on HP Integrity * |
Released: August 12, 2011 | | Documentation: B25152vi.html | | Download: B25152vi.exe |
|
| * Windows, Windows for IPF, Windows for x64, 64-bit Enabled HP-UX, 64-bit Enabled Solaris, 64-bit Enabled AIX, Linux, HP-UX IPF, Linux for x64, Solaris for x64, OpenVMS on HP Integrity: If you install this hot fix, you must install Base SAS hot fix B25206. |
| B25164 |
| Base SAS 9.21_M3 |
| Issue(s) Addressed: | Introduced: |
| 39626 | "Communication error with launch server" message when attempting to start a Workspace server or Stored Process server in SASŪ 9.2 |
B25024 |
| 40918 | Jobs that are submitted for the grid might fail to connect if you have applied Hot Fix B25024 |
B25042 |
| 44638 * | Using Standard AIX Kerberos configuration generates PAG style Kerberos Tickets resulting in tickets not being found |
B25164 |
| * Indicates that the fix for the issue described in this SAS Note does not apply to all Operating Systems. |
|
| D indicates that the Documentation has special pre-installation, post-installation or other unique instructions not commonly used for hot fix deployment. |
| B25183 |
| Base SAS 9.21_M3 |
| Issue(s) Addressed: | Introduced: |
| 39807 | Global macro variable values and scope may be set incorrectly when PROC RISK is within a macro |
B25007 |
| 40220 | EFI, PROC IMPORT and IMPORT WIZARD read a quoted 4 digit number incorrectly |
B25007 |
| 40252 | R interface in Proc IML does not work on 64-bit Windows Operating Systems |
B25012 |
| 40382 | CALL SYMPUT may not update existing global macro variable |
B25023 |
| 40438 | Extremely wide data sets created on a 64-bit operating system produce incorrect or missing values on 32-bit operating systems |
B25026 |
| 40521 | SAS appears to hang in an endless loop if you use Cross Environment Data Access (CEDA) and select a large number of variables |
B25026 |
| 40449 | ANYDTDTE doesn't read a period value properly |
B25034 |
| 40737 | Calling user defined functions using %SYSFUNC can result in an error or termination of SAS |
B25036 |
| 41114 | WHERE clauses that reference functions will execute slowly in SCL code |
B25058 |
| 41119 | Multiple WHERE ALSO statements in the DATA Step returns incorrect results or errors |
B25058 |
| 39768 | Existing client connections to SAS Workspace Servers are closed when the SAS Object Spawner is stopped or refreshed. |
B25086 |
| 41651 | Grid test found exposure to segmentation violation |
B25086 |
| 42252 | ALERT - DATA step views are not accessible when you submit and pass them to a SAS grid from SASŪ Enterprise GuideŪ |
B25086 |
| 31887 | Problems with macro variables Created in an AUTOEXEC.SAS file when executing SAS on a workspace server |
B25112 |
| 42925 | You cannot audit SASŪ library Open objects in the standard SAS logging facility |
B25112 |
| 43537 | The last character of a double-byte character set variable is truncated when the variable length is 257 |
B25138 |
| 43671 | A memory leak may occur in SASŪ Integration Technologies server processes. |
B25138 |
| 43967 | Indexes on data sets can become corrupt when run against the same data multiple times |
B25149 |
| 44190 | Unicode server performance is degraded when character literals in a WHERE clause are not passed to a database correctly |
B25158 |
| 39846 | Errors occur in a Foundation SASŪ session when you try to connect with a SASŪ Integration Technologies Server |
B25166 |
| 44674 | Referencing an autocall macro stored in a catalog causes a message window to appear upon exiting SAS |
B25170 |
| 45589 | An index might be ignored in BY processing after importing the indexed data set from transport format from another operating system |
B25183 |
NOTE: If you install this hot fix, you must also install hot fix B25202 for Base SAS 9.21_M3.
NOTE: SAS Integration Technologies customers must also install hot fix B25184 to fully implement the fix for the issue described in SN-39768. NOTE: SAS Enterprise Guide customers must also install hot fix B99008 to fully implement the fix for the issue described in SN-42252. |
| z/OS |
Released: February 09, 2012 | | Documentation: B25183os.html | | Download: B25183os.bin |
| Windows |
Released: February 09, 2012 | | Documentation: B25183wn.html | | Download: B25183wn.exe |
| Windows for IPF |
Released: February 09, 2012 | | Documentation: B25183w6.html | | Download: B25183w6.exe |
| Windows for x64 |
Released: February 09, 2012 | | Documentation: B25183x6.html | | Download: B25183x6.exe |
| 64-bit Enabled HP-UX |
Released: February 09, 2012 | | Documentation: B25183h6.html | | Download: B25183h6.bin |
| 64-bit Enabled Solaris |
Released: February 09, 2012 | | Documentation: B25183s6.html | | Download: B25183s6.bin |
| 64-bit Enabled AIX |
Released: February 09, 2012 | | Documentation: B25183r6.html | | Download: B25183r6.bin |
| Linux |
Released: February 09, 2012 | | Documentation: B25183lx.html | | Download: B25183lx.bin |
| HP-UX IPF |
Released: February 09, 2012 | | Documentation: B25183hx.html | | Download: B25183hx.bin |
| Linux for x64 |
Released: February 09, 2012 | | Documentation: B25183la.html | | Download: B25183la.bin |
| Solaris for x64 |
Released: February 09, 2012 | | Documentation: B25183sx.html | | Download: B25183sx.bin |
| OpenVMS on HP Integrity |
Released: February 09, 2012 | | Documentation: B25183vi.html | | Download: B25183vi.exe |
|
| B25184 |
| Base SAS 9.21_M3 |
| Issue(s) Addressed: | Introduced: |
| 38906 | The SAS metadata engine LIBNAME statement fails to interpret access password specification for the the Remote Engine Library server |
B25020 |
| 40125 | A slow response might occur when you connect to a SAS application server from client applications |
B25020 |
| 40366 | ALERT - The error "Libname _PMTA01_ is not assigned" occurs when you try to update metadata for a work table |
B25020 |
| 39371 | SASŪ Stored Process Server might hang during shut down if the SAS Workspace Server is being monitored |
B25031 |
| 40920 | You are denied access to the SAS Workspace Server after you use SASŪ Enterprise GuideŪ to connect to the SASŪ Metadata Server |
B25039 |
| 39768 | Existing client connections to SAS Workspace Servers are closed when the SAS Object Spawner is stopped or refreshed. |
B25054 |
| 41542 | ALERT - SAS Object Spawner may crash when shutting down a SAS Pooled Workspace Server. |
B25054 |
| 41921 | ERROR: ORACLE connection error: ORA-01017: invalid username/password; logon denied. |
B25077 |
| 42178 | SAS Workspace server connections may fail when the SASŪ Grid Manager load balancing algorithm is used. |
B25118 |
| 42746 | Performance degradation in the SAS 9.2 Pooled Workspace Server when querying SASŪ Information Maps |
B25118 |
| 43110 | SASŪ OLAP Server might stop responding when the number of connected clients is high |
B25121 |
| 43204 | The TIMEOUTSECONDS parameter might cause the SASŪ OLAP Server to stop responding |
B25130 |
| 43690 | Library allocation messages are incorrectly reported at the WARN level instead of INFO |
B25140 |
| 43570 | If one of the peers in a load balanced cluster of 3 or more peers is refreshed or restarted it causes load balancing to behave incorrectly. |
B25142 |
| 45627 | Improved functionality to detect and shutdown orphaned SAS Workspace Server processes |
B25184 |
| 45661 | Load balanced SASŪ OLAP Servers may abend and hang on shutdown |
B25184 |
NOTE: If you install this hot fix and need the fix documented in SAS Note 41921, you must also install Base SAS hot fix B25111.
If you install this hot fix and need the fix documented in SAS Note 43204, you must also install hot fix B25171 (z/OS only).
If you install this hot fix and need the fix documented in SAS Note 40125, you must also install Base SAS hot fix B25205.
If you install this hot fix and need the fix documented in SAS Note 39768, you must also install hot fix B25183. |
| z/OS |
Released: March 09, 2012 | | Documentation: B25184os.html | | Download: B25184os.bin |
| Windows |
Released: March 09, 2012 | | Documentation: B25184wn.html | | Download: B25184wn.exe |
| Windows for IPF |
Released: March 09, 2012 | | Documentation: B25184w6.html | | Download: B25184w6.exe |
| Windows for x64 |
Released: March 09, 2012 | | Documentation: B25184x6.html | | Download: B25184x6.exe |
| 64-bit Enabled HP-UX |
Released: March 09, 2012 | | Documentation: B25184h6.html | | Download: B25184h6.bin |
| 64-bit Enabled Solaris |
Released: March 09, 2012 | | Documentation: B25184s6.html | | Download: B25184s6.bin |
| 64-bit Enabled AIX |
Released: March 09, 2012 | | Documentation: B25184r6.html | | Download: B25184r6.bin |
| Linux |
Released: March 09, 2012 | | Documentation: B25184lx.html | | Download: B25184lx.bin |
| HP-UX IPF |
Released: March 09, 2012 | | Documentation: B25184hx.html | | Download: B25184hx.bin |
| Linux for x64 |
Released: March 09, 2012 | | Documentation: B25184la.html | | Download: B25184la.bin |
| Solaris for x64 |
Released: March 09, 2012 | | Documentation: B25184sx.html | | Download: B25184sx.bin |
| OpenVMS on HP Integrity |
Released: March 09, 2012 | | Documentation: B25184vi.html | | Download: B25184vi.exe |
|
| B25193 |
| Base SAS 9.21_M3 |
| Issue(s) Addressed: | Introduced: |
| 41008 | Variable spanned records with an LRECL= system option value greater than 32760 are not handled correctly in SASŪ 9.2 resulting in an ABEND002-4 |
B25045 |
| 40475 | SASŪ 9.2 creates an output file with a different logical record length (LRECL) than what is produced by SAS 8.2 |
B25055 |
| 40882 | Output from the PRINTTO procedure is produced as unblocked in SASŪ 9.2 |
B25055 |
| 41191 | The FILEVAR= option in the INFILE or FILE statement does not work properly with the INFILE/FILE user exit |
B25065 |
| 41261 | ALERT - A SASŪ job that is running in a z/OS 1.12 operating environment might stop responding when an external file I/O error occurs |
B25065 |
| 41866 | A system abend A03 occurs with an interactive SASŪ session |
B25073 |
| 41220 | Mixed-case passwords that are submitted to a SASŪ server in a z/OS operating environment return a security verification failure to the client |
B25110 |
| 45518 | Support of mixed-case passwords is not implemented in SASŪ 9.3 64-bit software |
B25110 |
| 42615 | An error might occur due to a space management problem that causes a SAS bound library size to grow without limit |
B25125 |
| 43137 | ALERT - SAS Enterprise Guide error saving stored process code when connected to z/OS |
B25125 |
| 43370 | PIBw.d informat reads valid value as zero on z/OS |
B25141 |
| 43488 | The WORK library is limited in how it can be allocated on a client or server machine in the z/OS operating environment |
B25141 |
| 43515 | SASŪ fails when you use a %INCLUDE statement that references an explicit data set stored on a volume whose serial name contains less than 6 characters |
B25146 |
| 43817 | A %INCLUDE statement for an externally allocated data set might fail in the z/OS environment |
B25146 |
| 45685 | System abend 0C4 occurs when the FILENAME option MGTCLAS is used with an unresolved macro variable |
B25146 |
| 45059 | The message "ERROR: SVC99 error rc=4, reason=02D6" occurs in SASŪ 9.2 when the UNIT value is not valid |
B25173 |
| 45363 | ALERT - Sorting a SASŪ data set using IBM DFSORT as the host sort utility might cause the last byte of the data set to be replaced with x'00' |
B25182 |
| 45596 | In SASŪ Enterprise GuideŪ 4.2 and 4.3, SAS libraries that are z/OS GDGs cannot be seen in the server list under Bound Libraries |
B25191 |
| 45711 | An intermittent abend or loop can occur due to a race condition |
B25191 |
| 45833 | UTILLOC files are not always allocated with optimal block size |
B25193 |
NOTE: Hot fix B25171 MUST be applied prior to applying B25193.
You must also install hot fix B25126 to fully implement the fixes for the issues addressed in this hot fix. |
|
| D indicates that the Documentation has special pre-installation, post-installation or other unique instructions not commonly used for hot fix deployment. |
| B25195 |
| Base SAS 9.21_M3 |
| Issue(s) Addressed: | Introduced: |
| 39997 | A database error can occur when you submit an SQL query with a LIBNAME statement that uses the MULTI_DATASRC_OPT=IN_CLAUSE option |
B25028 |
| 41745 | Accessing DB2 can result in System abend 0C4 in module SASIODB2 |
B25066 |
| 41748 | Using the LIBNAME option MULTI_DATASRC_OPT=IN_CLAUSE can result in an error |
B25066 |
| 43275 | A CLI error occurs when you access DB2 via SAS/ACCESSŪ 9.2 Interface to ODBC and PROC SQL implicit pass-through processing |
B25117 |
| 45162 | ALERT - Slow performance and incorrect results might occur if you use DBCREATE_TABLE_OPTS to create a primary index for a Teradata table |
B25195 |
NOTE: If you install this hot fix, you should also install Base SAS 9.21_M3 hot fix B25202.
Customers running SAS/ACCESS Interface to DB2 9.21_M2 must also install hot fix B94015.
Customers running SAS/ACCESS Interface to Teradata 9.21_M2 must also install hot fix C71006.
Customers running SAS/ACCESS Interface to Teradata 9.21_M1 on Windows for x64 must also install hot fix D35005.
Customers running SAS/ACCESS Interface to Oracle 9.21_M2 must also install hot fix C36004. |
| z/OS |
Released: March 28, 2012 | | Documentation: B25195os.html | | Download: B25195os.bin |
| Windows |
Released: March 28, 2012 | | Documentation: B25195wn.html | | Download: B25195wn.exe |
| Windows for IPF |
Released: March 28, 2012 | | Documentation: B25195w6.html | | Download: B25195w6.exe |
| Windows for x64 |
Released: March 28, 2012 | | Documentation: B25195x6.html | | Download: B25195x6.exe |
| 64-bit Enabled HP-UX |
Released: March 28, 2012 | | Documentation: B25195h6.html | | Download: B25195h6.bin |
| 64-bit Enabled Solaris |
Released: March 28, 2012 | | Documentation: B25195s6.html | | Download: B25195s6.bin |
| 64-bit Enabled AIX |
Released: March 28, 2012 | | Documentation: B25195r6.html | | Download: B25195r6.bin |
| Linux |
Released: March 28, 2012 | | Documentation: B25195lx.html | | Download: B25195lx.bin |
| HP-UX IPF |
Released: March 28, 2012 | | Documentation: B25195hx.html | | Download: B25195hx.bin |
| Linux for x64 |
Released: March 28, 2012 | | Documentation: B25195la.html | | Download: B25195la.bin |
| Solaris for x64 |
Released: March 28, 2012 | | Documentation: B25195sx.html | | Download: B25195sx.bin |
| OpenVMS on HP Integrity |
Released: March 28, 2012 | | Documentation: B25195vi.html | | Download: B25195vi.exe |
|
| B25198 |
| Base SAS 9.21_M3 |
| Issue(s) Addressed: | Introduced: |
| 39833 | The SASŪ Metadata Server might terminate abnormally |
B25001 |
| 41201 | The SASŪ Metadata Server might report that the members of the SAS Metadata Server fixed roles no longer have the associated privileges |
B25051 |
| 42284 | The EXPORT Wizard may fail with: [Fatal Error] :154:345: An invalid XML character |
B25075 |
| 42768 | Long member-level permission conditions for SASŪ OLAP cubes might cause the SASŪ Metadata Server to fail |
B25115 |
| 43114 | An error might occur when you use SASŪ Management Console to change the association of one metadata object to another |
B25115 |
| 45686 | New SASŪ Metadata Server logging functionality is available with SASŪ 9.2 TS2M3 hot fix |
B25190 |
| 46160 | Check In fails with an "Error checking in metadata.." error in SASŪ Data Integration Studio |
B25198 |
| z/OS |
Released: April 09, 2012 | | Documentation: B25198os.html | | Download: B25198os.bin |
| Windows |
Released: April 09, 2012 | | Documentation: B25198wn.html | | Download: B25198wn.exe |
| Windows for IPF |
Released: April 09, 2012 | | Documentation: B25198w6.html | | Download: B25198w6.exe |
| Windows for x64 |
Released: April 09, 2012 | | Documentation: B25198x6.html | | Download: B25198x6.exe |
| 64-bit Enabled HP-UX |
Released: April 09, 2012 | | Documentation: B25198h6.html | | Download: B25198h6.bin |
| 64-bit Enabled Solaris |
Released: April 09, 2012 | | Documentation: B25198s6.html | | Download: B25198s6.bin |
| 64-bit Enabled AIX |
Released: April 09, 2012 | | Documentation: B25198r6.html | | Download: B25198r6.bin |
| Linux |
Released: April 09, 2012 | | Documentation: B25198lx.html | | Download: B25198lx.bin |
| HP-UX IPF |
Released: April 09, 2012 | | Documentation: B25198hx.html | | Download: B25198hx.bin |
| Linux for x64 |
Released: April 09, 2012 | | Documentation: B25198la.html | | Download: B25198la.bin |
| Solaris for x64 |
Released: April 09, 2012 | | Documentation: B25198sx.html | | Download: B25198sx.bin |
|
| B25202 |
| Base SAS 9.21_M3 |
| Issue(s) Addressed: | Introduced: |
| 39125 | An SQLPLAN error might occur when you use a new column variable in a correlated subquery |
B25021 |
| 39129 | Formatting a newly created, missing numeric variable might result in a "Format not found" error |
B25021 |
| 39304 | SQL views of DBMS tables may not return aliased column names |
B25021 |
| 39984 | An SQL procedure view does not return any rows when it is used in DATA step or a PRINT procedure |
B25021 |
| 40714 | SQL procedure queries might take longer to run in SASŪ 9.2 TS2M2 and TS2M3 |
B25021 |
| 41875 | SAS/ACCESSŪ Interface to DB2 might produce incorrect results when left joining two or more DB2 tables |
B25053 |
| 41619 | Using PROC FORMAT in conjunction with PROC SQL to access a database gives different results between SASŪ 9.1.3 and SASŪ 9.2 |
B25060 |
| 41785 | Read Access Violation errors occur when creating a long macro variable with the PROC SQL / INTO: macro interface |
B25060 |
| 34687 | ALERT - Incorrect results might occur if you use the PUT() function in a WHERE clause to convert a DB2 timestamp to a character value |
B25083 |
| 38759 | An error can occur when you run a query against a DBMS and the query contains a column that is renamed and that is then used in a GROUP BY clause |
B25083 |
| 42093 | Using the PROC SQL BTRIM() function causes insufficient memory errors |
B25083 |
| 43970 | Errors occur when you use input() or put() in a JOIN operation with a database table in a remote library |
B25083 |
| 44688 | An INPUT() function used in PROC SQL might return incorrect results |
B25083 |
| 42425 | SQLPLAN error might occur when creating a new variable based on another new variable |
B25116 |
| 43021 | The SASŪ System might not consider the DBKEY= data set option when you join a SAS data set and a DBMS table |
B25116 |
| 43262 | Queries that reference tables in libraries that are assigned using the META libname engine might perform poorly |
B25134 |
| 42737 | ALERT - Incorrect results occur in implicit pass-through when you use CALCULATED keyword on GROUP BY statement |
B25157 |
| 43787 | Performance is adversely affected by SQL queries that use unique indexes through SAS/SHAREŪ software |
B25157 |
| 44069 | Performance might be affected if your query joins multiple tables or views in which variables are being renamed |
B25157 |
| 44190 | Unicode server performance is degraded when character literals in a WHERE clause are not passed to a database correctly |
B25157 |
| 45162 | ALERT - Slow performance and incorrect results might occur if you use DBCREATE_TABLE_OPTS to create a primary index for a Teradata table |
B25196 |
| 45689 | The SASŪ Stored Process Server might stop functioning properly if you cancel a request that is running PROC SQL code |
B25202 |
NOTE: If you install this hot fix, you should also install Base SAS 9.21_M3 hot fixes B25205, B25183, and B25195.
Customers running SAS/ACCESS Interface to Teradata 9.21_M2 must also install hot fix C71006.
Customers running SAS/ACCESS Interface to Teradata 9.21_M1 on Windows for x64 must also install hot fix D35005.
Customers running SAS/ACCESS Interface to Oracle 9.21_M2 must also install hot fix C36004. |
| z/OS |
Released: May 09, 2012 | | Documentation: B25202os.html D | | Download: B25202os.bin |
| Windows |
Released: May 09, 2012 | | Documentation: B25202wn.html D | | Download: B25202wn.exe |
| Windows for IPF |
Released: May 09, 2012 | | Documentation: B25202w6.html D | | Download: B25202w6.exe |
| Windows for x64 |
Released: May 09, 2012 | | Documentation: B25202x6.html D | | Download: B25202x6.exe |
| 64-bit Enabled HP-UX |
Released: May 09, 2012 | | Documentation: B25202h6.html D | | Download: B25202h6.bin |
| 64-bit Enabled Solaris |
Released: May 09, 2012 | | Documentation: B25202s6.html D | | Download: B25202s6.bin |
| 64-bit Enabled AIX |
Released: May 09, 2012 | | Documentation: B25202r6.html D | | Download: B25202r6.bin |
| Linux |
Released: May 09, 2012 | | Documentation: B25202lx.html D | | Download: B25202lx.bin |
| HP-UX IPF |
Released: May 09, 2012 | | Documentation: B25202hx.html D | | Download: B25202hx.bin |
| Linux for x64 |
Released: May 09, 2012 | | Documentation: B25202la.html D | | Download: B25202la.bin |
| Solaris for x64 |
Released: May 09, 2012 | | Documentation: B25202sx.html D | | Download: B25202sx.bin |
| OpenVMS on HP Integrity |
Released: May 09, 2012 | | Documentation: B25202vi.html D | | Download: B25202vi.exe |
|
| D indicates that the Documentation has special pre-installation, post-installation or other unique instructions not commonly used for hot fix deployment. |
| B25205 |
| Base SAS 9.21_M3 |
| Issue(s) Addressed: | Introduced: |
| 38906 | The SAS metadata engine LIBNAME statement fails to interpret access password specification for the the Remote Engine Library server |
B25018 |
| 40125 | A slow response might occur when you connect to a SAS application server from client applications |
B25018 |
| 40231 | "ERROR: Libname _PMTA01_ is not assigned" occurs when running the METALIB procedure |
B25018 |
| 40366 | ALERT - The error "Libname _PMTA01_ is not assigned" occurs when you try to update metadata for a work table |
B25018 |
| 39550 | A Read access violation occurs when you use the METALIB procedure to import or register database tables into the SASŪ Metadata Repository |
B25056 |
| 38707 | An error occurs when you add the DBSASTYPE= option to a database table in SASŪ Management Console and you run a query that uses the metadata engine |
B25123 |
| 43224 | An error message appears in your SASŪ log if you use the METALIB procedure to register or update a view that is defined in a Sybase database |
B25123 |
| 43262 | Queries that reference tables in libraries that are assigned using the META libname engine might perform poorly |
B25123 |
| 44153 | Libraries referenced in PROC METALIB or a META LIBNAME statement look for DBMS credentials in metadata even when Authentication Type is "NONE" |
B25159 |
| 44180 | "ERROR: Read Access Violation In Task [SQL]" might occur when using the META engine on a LIBNAME statement |
B25159 |
| 41093 | An error occurs and you cannot access an Oracle table when you use a schema name or a user ID that contains a dollar sign ($) |
B25205 |
| 46153 | The META libname engine ignores the Default Login associated with a relational database library |
B25205 |
| 46405 | META libname engine no longer reports column length inconsistencies when it should |
B25205 |
| 46408 | Access to third party database tables via the META libname engine fails when the userid contains special characters |
B25205 |
| NOTE: If you install this hot fix, you should also install Base SAS 9.21_M3 hot fixes B25184 and B25202. |
| z/OS |
Released: May 04, 2012 | | Documentation: B25205os.html | | Download: B25205os.bin |
| Windows |
Released: May 04, 2012 | | Documentation: B25205wn.html | | Download: B25205wn.exe |
| Windows for IPF |
Released: May 04, 2012 | | Documentation: B25205w6.html | | Download: B25205w6.exe |
| Windows for x64 |
Released: May 04, 2012 | | Documentation: B25205x6.html | | Download: B25205x6.exe |
| 64-bit Enabled HP-UX |
Released: May 04, 2012 | | Documentation: B25205h6.html | | Download: B25205h6.bin |
| 64-bit Enabled Solaris |
Released: May 04, 2012 | | Documentation: B25205s6.html | | Download: B25205s6.bin |
| 64-bit Enabled AIX |
Released: May 04, 2012 | | Documentation: B25205r6.html | | Download: B25205r6.bin |
| Linux |
Released: May 04, 2012 | | Documentation: B25205lx.html | | Download: B25205lx.bin |
| HP-UX IPF |
Released: May 04, 2012 | | Documentation: B25205hx.html | | Download: B25205hx.bin |
| Linux for x64 |
Released: May 04, 2012 | | Documentation: B25205la.html | | Download: B25205la.bin |
| Solaris for x64 |
Released: May 04, 2012 | | Documentation: B25205sx.html | | Download: B25205sx.bin |
| OpenVMS on HP Integrity |
Released: May 04, 2012 | | Documentation: B25205vi.html | | Download: B25205vi.exe |
|
| B25206 |
| Base SAS 9.21_M3 |
| Issue(s) Addressed: | Introduced: |
| 40822 * | Specifying the SASŪ system option OPLIST may cause a segmentation violation error in the UNIX environment |
B25046 |
| 41013 | Errors might occur when you use the SASTRACE= system option with the SAS/ACCESSŪ engines |
B25046 |
| 37059 * | ERROR: "Read access violation in task [ DATASTEP ]" might occur when running SASŪ 9.2 on Microsoft Windows x64 and 64-bit Itanium-based systems |
B25049 |
| 41510 * | Installation fails if hostname does not match SID file or if hostname is longer than 11 characters on Unix platforms |
B25061 |
| 40157 * | SASŪ 9.2 ignores SGIO processing in a Windows x64 operating environment |
B25078 |
| 41115 | Loading a large SAS data file into memory can cause macro slowdown |
B25078 |
| 41574 | Double-byte character sets (DBCS) might not display properly in the ARM log |
B25078 |
| 42240 | The LIBNAME statement's FILELOCKWAIT= option might not check for a lock in all cases |
B25078 |
| 42376 * | An error occurs when reading a filename that includes an asterisk (*) with the Japanese edition of SASŪ 9.2 in a Windows operating environment |
B25092 |
| 42392 * | Truncated value for automatic macro variable &SYSPROCESSNAME |
B25104 |
| 42394 * | Number of open files decreases when opening/closing a data set over multiple iterations |
B25104 |
| 42857 | Poor performance when reading non-local files with SASŪ 9.2 on OpenVMS on HP Integrity |
B25109 |
| 43126 * | CPU time limit set via ulimit -t is ignored |
B25124 |
| 42894 * | SHR= option on a FILENAME statement is not honored |
B25129 |
| 42969 * | "Invalid data" note received when reading files with variable-length records using DECNET |
B25129 |
| 42974 * | Erroneous data set created when reading a file with fixed-length records when there is an odd number of bytes per record |
B25129 |
| 42998 * | Performance degradation occurs when dividing with missing values |
B25129 |
| 43448 * | Segmentation violation error in sasmotif module on OracleŪ Solaris 11 Express |
B25133 |
| 43943 * | SASŪ Scalable Performance Data ServerŪ on Windows might experience problems with performance or appear unresponsive |
B25145 |
| 43857 * | When creating external files containing fixed-length records, record attributes are created as NONE |
B25148 |
| 43858 * | SASŪ 9.2 creates an incorrectly formatted fixed-length record file when the record length is an odd number |
B25148 |
| 43920 * | Specifying the Albany AMT font when creating SAS/GRAPHŪ output can cause SASŪ to fail |
B25148 |
| 44733 * | Font list in the DLGFONT window contains garbled characters |
B25148 |
| 39397 * | Using SYSTASK statement to submit UNIX command causes error if SHELL= is specified |
B25161 |
| 44472 | Overwriting a SASŪ data set in a UNIX operating environment removes any existing ACL |
B25165 |
| 44585 * | Large DATA Step may go into infinite loop on AIX (64-bit) systems |
B25165 |
| 44584 | SASŪ Enterprise GuideŪ does not import UTF-16 files correctly using a UTF-8 SASŪ server |
B25167 |
| 44729 * | FULLSTIMER statistics for Memory usage are not correct when using SASŪ Enterprise Guide to connect to a UNIX server |
B25167 |
| 45369 * | "Utility file open failed" might appear when attempting to build a SASŪ OLAP cube |
B25178 |
| 39615 * | ALERT - Input/output performance in SASŪ is degraded due to excessive memory usage on Windows |
B25188 |
| 45522 * | IGNOREDOSEOF option not honored when specified on the FILENAME statement |
B25188 |
| 45632 * | Queries against the SASŪ OLAP Server on Microsoft Windows might use excessive memory due to a Windows cache manager issue |
B25188 |
| 45507 * | FILEEXIST causes an infinite loop on Unix if path equates to the root directory |
B25199 |
| 45225 * | Installation with a sub-capacity license fails if hyper-threading has been enabled |
B25201 |
| 46251 | Directories cannot be created under the Files folder in SASŪ Enterprise GuideŪ |
B25206 |
| * Indicates that the fix for the issue described in this SAS Note does not apply to all Operating Systems. |
| Windows |
Released: May 14, 2012 | | Documentation: B25206wn.html | | Download: B25206wn.exe |
| Windows for IPF |
Released: May 14, 2012 | | Documentation: B25206w6.html | | Download: B25206w6.exe |
| Windows for x64 |
Released: May 14, 2012 | | Documentation: B25206x6.html | | Download: B25206x6.exe |
| 64-bit Enabled HP-UX |
Released: May 14, 2012 | | Documentation: B25206h6.html | | Download: B25206h6.bin |
| 64-bit Enabled Solaris |
Released: May 14, 2012 | | Documentation: B25206s6.html | | Download: B25206s6.bin |
| 64-bit Enabled AIX |
Released: May 14, 2012 | | Documentation: B25206r6.html | | Download: B25206r6.bin |
| Linux |
Released: May 14, 2012 | | Documentation: B25206lx.html | | Download: B25206lx.bin |
| HP-UX IPF |
Released: May 14, 2012 | | Documentation: B25206hx.html | | Download: B25206hx.bin |
| Linux for x64 |
Released: May 14, 2012 | | Documentation: B25206la.html | | Download: B25206la.bin |
| Solaris for x64 |
Released: May 14, 2012 | | Documentation: B25206sx.html | | Download: B25206sx.bin |
| OpenVMS on HP Integrity |
Released: May 14, 2012 | | Documentation: B25206vi.html | | Download: B25206vi.exe |
|
| B25207 |
| Base SAS 9.21_M3 |
| Issue(s) Addressed: | Introduced: |
| 39480 | Queries that contain the PROPERTIES function might return a formula error on some operating systems |
B25002 |
| 39955 | ALERT - VisualTotals and other calculated members might return unexpected values in OLAP-based reporting |
B25006 |
| 40077 | MDX to-date functions might return incorrect values when used with other calculated members |
B25006 |
| 40091 | AGGREGATE_TOTAL function in the SASŪ OLAP Server can restrict access to members with unexpected results |
B25032 |
| 40549 | Optimization code might cause additional queries when accessing aggregation data |
B25032 |
| 40550 | VisualTotals with MDX functions using the .CURRENTMEMBER function can return unexpected results |
B25032 |
| 40551 | Performance issues might occur when using flattened results from MDX queries after appying hot fix B25006 |
B25032 |
| 41005 | Use of the NONEMPTYCROSSJOIN function and multiple-selection filters might result in missing rows |
B25063 |
| 41078 | Queries to SAS OLAP cubes that are built using ROLAP or external aggregations might perform slowly |
B25063 |
| 41175 | SECURITY_SUBSET not honored for totals after import of cube metadata |
B25063 |
| 41234 | The NonEmptyCrossjoin function might return incorrect results after applying hot fix B25032 |
B25063 |
| 41637 | Large memory usage might occur on Solaris machines when an invalid dimension name is used in the VisualTotals_Behavior property |
B25063 |
| 41642 | Multiple member filters on the hidden dimension or slicer axis might return incorrect results when totals are displayed on both rows and columns |
B25063 |
| 40911 | Do not use reserved words in dimension names when working with external aggregations |
B25103 |
| 41577 | Queries might perform slowly if ties are included when using TOPCOUNT |
B25103 |
| 41939 | Columns for categorical data that contain only missing values might be removed from the output of a flattened OLAP query |
B25103 |
| 42160 | Variables with more than 16777215 unique values cause a floating point exception in PROC OLAP |
B25103 |
| 37161 | SASŪ OLAP Data Provider does not allow users to disable the "Include Hidden Items in totals" option in Microsoft Excel |
B25136 |
| 42406 | SASŪ session might stop responding when using the DISABLE CUBES statement |
B25136 |
| 42827 | Drill-through to detail data for an OLAP cube might fail if UTF-8 encoding is used and member values contain non-English characters |
B25136 |
| 43542 | "The server encountered an error accessing a source data table" received when macro references exist in a member caption for a ROLAP cube |
B25136 |
| 43554 | PROC OLAPOPERATE and other administrative calls to the SASŪ OLAP Server could cause the OLAP Server to fail |
B25136 |
| 43556 | Options NECJPERCENTTOTAL and NECJWHEREMAX have been added to the SASŪ OLAP Server to help disable NONEMPTY CROSSJOIN optimization for dense data |
B25136 |
| 43557 | SQL range optimization is bypassed for data ordered by formatted values for a SASŪ OLAP cube |
B25136 |
| 44260 | Continuous DISABLE CUBE operations might cause the SASŪ OLAP Server to stop responding |
B25155 |
| 44267 | MDX ORDER function might generate a large number of subqueries |
B25155 |
| 44277 | Final subquery to satisfy a query against a SASŪ OLAP cube might be unnecessary and impact performance |
B25155 |
| 44715 | Performance enhancement enables the underlying data source to calculate TOPCOUNT and BOTTOMCOUNT for an OLAP query |
B25168 |
| 44742 | General performance improvements for SASŪ OLAP cubes are included with Hot Fix B25168 for the third maintenance release for SAS 9.2 (TS2M3) |
B25168 |
| 44751 | Poor performance when drilling to detail data from a SASŪ OLAP cube |
B25168 |
| 42667 | Empty results from a non empty crossjoin query might result in slow performance from the SASŪ OLAP Server |
B25192 |
| 45266 | Visual totals might be incorrect when single member on slicer and two hierarchies from the same dimension are on different axes |
B25192 |
| 45491 | "Error: Insufficient memory" might appear when very large sets are crossjoined and the maximum number of members is exceeded |
B25192 |
| 45608 | "Read Access Violation" using DATAPATH or INDEXPATH options creating SPDE library |
B25192 |
| 45633 | Read Access Violation might be generated for PROC OLAP when there are many levels in a dimension with multiple hierarchies |
B25192 |
| 46447 | The ORDER function might return incorrect results when the default measure is used in both the set and the numeric expression parameters |
B25207 |
| 46550 | The SASŪ OLAP Server might stop responding after a client attempts to cancel a query that is running on the SAS OLAP Server |
B25207 |
| z/OS * |
Released: May 22, 2012 | | Documentation: B25207os.html | | Download: B25207os.bin |
| Windows * |
Released: May 21, 2012 | | Documentation: B25207wn.html | | Download: B25207wn.exe |
| Windows for IPF * |
Released: May 21, 2012 | | Documentation: B25207w6.html | | Download: B25207w6.exe |
| Windows for x64 * |
Released: May 21, 2012 | | Documentation: B25207x6.html | | Download: B25207x6.exe |
| 64-bit Enabled HP-UX * |
Released: May 21, 2012 | | Documentation: B25207h6.html | | Download: B25207h6.bin |
| 64-bit Enabled Solaris * |
Released: May 21, 2012 | | Documentation: B25207s6.html | | Download: B25207s6.bin |
| 64-bit Enabled AIX * |
Released: May 21, 2012 | | Documentation: B25207r6.html | | Download: B25207r6.bin |
| Linux * |
Released: May 21, 2012 | | Documentation: B25207lx.html | | Download: B25207lx.bin |
| HP-UX IPF * |
Released: May 21, 2012 | | Documentation: B25207hx.html | | Download: B25207hx.bin |
| Linux for x64 * |
Released: May 21, 2012 | | Documentation: B25207la.html | | Download: B25207la.bin |
| Solaris for x64 * |
Released: May 21, 2012 | | Documentation: B25207sx.html | | Download: B25207sx.bin |
|
| * All Operating Systems: You must also install hot fixes B25169, B25176 and D28008 to fully implement the fixes for the issues addressed in this hot fix. |
| B25209 |
| Base SAS 9.21_M3 |
| Issue(s) Addressed: | Introduced: |
| 40061 | An error occurs when you set the font option to 10 point Courier in SASŪ 9.2 (TS2M0) that uses a Thai_Thailand locale |
B25050 |
| 41621 | Selecting "Save as HTML" does not save the data set in the redirected folder and SASŪ might terminate unexpectedly |
B25050 |
| 36548 | When you maximize the Properties dialog box for a SASŪ data set, only 17 columns of the data set display and tabs might not be visible |
B25081 |
| 37700 | Part of the variable listing of a data set appears to be blank when you view the data set in SAS Explorer |
B25081 |
| 42506 | Text color for Microsoft Windows host controls might not be honored in a SAS/AFŪ Frame |
B25101 |
| 42729 | SASŪ 9.2 overlays the Windows Forms API when you invoke SAS as an OLE automation server from a Microsoft Visual Basic application |
B25101 |
| 43112 | The SASŪ system might become unresponsive or close unexpectedly when converting SASŪ6 data sets to SASŪ9 data sets |
B25122 |
| 44994 | Using the Find dialog box to search in the SAS Log window might cause SASŪ 9.2 and SASŪ 9.3 to stop responding |
B25172 |
| 45003 | A general critical error occurs when you are paging up or down or when you are clearing the output window in SASŪ 9.3 |
B25172 |
| 46076 | Problems occur when you submit code to an OLE Automation Server when the SASŪ code contains embedded CRLF characters |
B25200 |
| 37304 | SAS/AFŪ TextPad control might return incorrect information in a DBCS environment |