D35006 |
SAS/ACCESS Interface to Teradata 9.21_M1 |
Issue(s) Addressed: | Introduced: |
41435 | The Teradata Parallel Transporter (TPT) is not supported when you use Lightweight Directory Access Protocol (LDAP) authentication |
D35001 |
41596 | Keys and indexes that are associated with Teradata tables are not properly registered or updated in the metadata |
D35001 |
41601 | Integrity constraints might not import into metadata when you import them from the Teradata database |
D35001 |
41669 | Teradata FastLoad sessions might fail when you set the SLEEP= and the TENACITY= data set options |
D35001 |
43172 | A system crash might occur when you run concurrent bulk-loading processes with SAS/ACCESS® Interface to Teradata |
D35001 |
38873 | A UTY4015 access-module error occurs when you use the Teradata MultiLoad utility with SAS/ACCESS® Interface to Teradata |
D35002 |
43257 | The error "WZX: origin buffer overflowed" occurs when you access Teradata tables via SAS/CONNECT® or SAS/SHARE® software |
D35002 |
43311 | The Teradata Parallel Transporter requires character-set specification for multi-byte clients at library initialization |
D35002 |
44420 | No members are shown in a Teradata library |
D35002 |
44698 | The UPSERT data set option is not supported when you are using the Teradata Parallel Transporter (TPT) with the MULTILOAD data set option |
D35002 |
44186 | LOGDB is not a supported option when using the Teradata Parallel Transporter (TPT) with SAS/ACCESS® Interface to Teradata |
D35003 |
45099 | ALERT - When data of type VARCHAR is extracted from a Teradata table with SAS/SHARE® software, the column data is truncated |
D35003 |
45789 | The default database is used for the log file for Teradata Parallel Transporter instead of the one that is specified in the DATABASE parameter |
D35004 |
46045 | Null values are loaded as blanks when using the Teradata Parallel Transporter (TPT) application |
D35004 |
46063 | One- and two-byte character fields are truncated when you are using SAS/SHARE® with SAS/ACCESS® Interface to Teradata |
D35004 |
46066 | If you apply Hot Fix C71004, the default database is used with TPT instead of the database specified in the DATABASE= option |
D35004 |
45162 | ALERT - Slow performance and incorrect results might occur if you use DBCREATE_TABLE_OPTS to create a primary index for a Teradata table |
D35005 |
50964 | When you open a Teradata library in SAS® Enterprise Guide®, the library takes a long time to open |
D35006 |
NOTE: If you install this hot fix, you must also install hot fixes B25219 and B25226 for Base SAS 9.21_M3.
NOTE: This hot fix is available for Windows for x64. Customers running on all other platforms must install hot fix C71007 instead. |
|
D indicates that the Documentation has special pre-installation, post-installation or other unique instructions not commonly used for hot fix deployment. |