Providing software solutions since 1976


Scalable Performance Data Server 4.52

Hot Fix Downloads for 64-bit Enabled AIX

* Important changes to Hot Fixes!

B57001 was replaced by B57006

B57002 was replaced by B57006

B57003 was replaced by B57006

B57004 was replaced by B57006

B57005 was replaced by B57006

B57006 for 64-bit Enabled AIX
Scalable Performance Data Server 4.52
Issue(s) Addressed:Introduced:
39713 ALERT - Required SASŪ Scalable Performance Data Server 4.52 hot fix removes JOIN optimization change B57001
40498 SASŪ Scalable Performance Data Server STAR JOIN fails when CLUSTER tables for DIMENSION tables do not have a unique index B57001
40499 SASŪ Scalable Performance Data ServerŪ queries limited to 4 hash joins B57001
40536 Index greater than 2GB on Windows cannot be used with SASŪ Scalable Performance Data Server B57001
40553 ALERT - Parallel WHERE clause evaluation returns incorrect results for implicit and explicit pass-through B57001
40663 ALERT - Incorrect results returned when the data set option NOINDEX=YES is used on a cluster table B57002
41185 SASŪ Scalable Performance Data Server 4.52 supports usernames that begin with numerics B57002
44425 Campaigns and diagrams might fail to complete execution or fail to connect to the database when they use the SASŪ Scalable Performance Data Server B57002
41011 ALERT - Use of HAVING clause with SQL GROUP BY may return incorrect results B57003
41534 ALERT - Incorrect results occur when Boolean logic is used in WHERE and HAVING clauses B57004
41666 SASŪ Management Console plug-in for SASŪ Scalable Performance Data Server becomes unresponsive when using the Password Manager B57004
42380 Spurious notes reported when accessing user-defined formats in SASŪ Scalable Performance Data Server B57004
42390 ALERT - Incorrect results generated for heterogeneous SQL JOIN in SASŪ Scalable Performance Data ServerŪ B57004
42396 SASŪ Scalable Performance Data ServerŪ can become unresponsive after refreshing domains when a large number of domains are defined B57004
42455 CLUSTER CREATE with single-member table having a unique index causes server to disconnect B57004
42464 SASŪ Scalable Performance Data ServerŪ parser issue when WHERE predicate contains NLS characters on Linux for x86_64 B57004
42472 SQL Pass-through extensions COPY TABLE and LOAD TABLE are not supported between SPD Server domains that have different backup attributes B57004
42535 Using PROC SQL to delete rows from a SASŪ Scalable Performance Data ServerŪ table might fail if DYNLOCK=YES is set in a LIBNAME statement B57004
43665 SASŪ Scalable Performance Data ServerŪ not using SRVOPORT value set in rc.spds script file B57005
43943 SASŪ Scalable Performance Data ServerŪ on Windows might experience problems with performance or appear unresponsive B57005
43944 STARJOIN performance problem caused by default value of STARSIZE memory B57005
43945 Long table name in SQL JOIN might cause SASŪ Scalable Performance Data ServerŪ to disconnect in a Windows environment B57005
43949 Listing or exporting users in the SASŪ Scalable Performance Data ServerŪ password database may return incomplete results B57005
43965 Segmentation violation error might occur with a large number of ACL entries B57005
43966 ALERT - Results of query against a very large SASŪ Scalable Performance Data ServerŪ table might be incorrect B57005
43999 LDAP authentication might fail when running SASŪ Scalable Performance Data ServerŪ 4.52 in a Windows environment B57005
44012 Thread initialization error generated for parallel join in SASŪ Scalable Performance Data ServerŪ B57005
41656 ALERT - SASŪ Scalable Performance Data Server WHERE constraints not honored in Viewtable window B57006
44863 Parallel index creation with SASŪ Scalable Performance Data ServerŪ on AIX 6.1 causes performance degradation B57006
45436 SASŪ Scalable Performance Data ServerŪ DICTIONARY tables return incorrect observation count B57006
45446 DBIDIRECTEXEC option causes SASŪ Scalable Performance Data ServerŪ table partitions to be written in the metadata path B57006
45456 "SPDS_ERROR: Parse Failure" when using LENGTH column attribute in SQL pass-through B57006
45457 Index names are truncated to 8 characters with SASŪ Scalable Performance Data ServerŪ B57006
45468 ALERT - WHERE constraints on SASŪ Scalable Performance Data ServerŪ tables are ignored when using record-level connection to the server B57006
45474 In SASŪ Scalable Performance Data ServerŪ, truncation occurs when the length of a concatenated string exceeds 200 characters B57006
45497 PROC SPDO CLUSTER CREATE or CLUSTER ADD might fail due to incompatible IDXSEGSIZE B57006
NOTE: If you install this hot fix, you must also install hot fix C34006 for Scalable Performance Data Client 4.52 on your client machine(s).
Released: January 31, 2012     Documentation: B57006r6.html       Download: B57006r6.bin  
Top ^

C34001 was replaced by C34006

C34002 was replaced by C34006

C34004 was replaced by C34006

C34005 was replaced by C34006

C34006 for 64-bit Enabled AIX
Scalable Performance Data Client 4.52 hot fix for Scalable Performance Data Server 4.52
Issue(s) Addressed:Introduced:
40768 SASŪ Scalable Performance Data Server does not support the LOCK statement C34001
41184 Issuing a SASŪ Scalable Performance Data ServerŪ LIBNAME statement with Remote Library Services gives spurious message that library does not exist C34001
41203 Support for the PROC SORT option PRESORTED added with SASŪ Scalable Performance Data Server 4.52 C34001
40869 "ERROR: Read Access Violation in Task[SPDO(2)]" might occur when using pre-assigned library in SASŪ Enterprise Guide C34002
41185 SASŪ Scalable Performance Data Server 4.52 supports usernames that begin with numerics C34002
13562 CHAR compressed SAS tables cannot be copied to SAS Scalable Performance Data Server C34004
42480 Adding multiple users to SASŪ Scalable Performance Data ServerŪ LIBNAME ACL statement causes incorrect note C34004
42483 ALERT - Incorrect result shown in note written to SAS log when a SASŪ Scalable Performance Data ServerŪ table is updated using the UNIQUESAVE=REP option C34004
45456 "SPDS_ERROR: Parse Failure" when using LENGTH column attribute in SQL pass-through C34006
45495 "Read Access Violation" error occurs when running PROC CONTENTS on SASŪ Scalable Performance Data ServerŪ cluster with a large number of members C34006
NOTE: If you install this hot fix, you must also install hot fix B57006 for Scalable Performance Data Server 4.52 on your server machine(s).
Released: January 31, 2012     Documentation: C34006r6.html       Download: C34006r6.bin  
Top ^




PLEASE CAREFULLY READ THE TERMS AND CONDITIONS OF THIS LICENSE AGREEMENT ("AGREEMENT") BEFORE DOWNLOADING MATERIALS FROM THIS SITE. BY DOWNLOADING ANY MATERIALS FROM THIS SITE, YOU ARE AGREEING TO THESE TERMS.
You are downloading software code ("Code") which will become part of a product ("Software") you currently have licensed from SAS Institute Inc. or one of its subsidiaries ("the Institute"). this Code is designed to either correct an error in the Software or to add functionality to the Software. The code is governed by the same agreement which governs the Software. If you do not have an existing agreement with the Institute governing the Software, you may not download the Code.
SAS and all other SAS Institute Inc. product or service names are registered trademarks or trademarks of SAS Institute Inc. in the USA and other countries. ® indicates USA registration. Other brand and product names are registered trademarks or trademarks of their respective companies.

Copyright © 2011 SAS Institute Inc. All Rights Reserved.