Hot fix K78001 addresses the issue(s) in SAS Marketing Automation 6.1_M1 as documented
in the Issue(s) Addressed section of the hot fix download page:
http://ftp.sas.com/techsup/download/hotfix/HF2/K78.html#K78001
K78001 is a "container" hot fix that contains the following "member" hot fixes which will update the software components
as indicated.
K72001 updates Marketing Automation Launcher 6.1_M1
K67001 updates SAS Customer Intelligence Common Logical Types 6.1_M1
K79001 updates SAS Customer Intelligence Core Mid-Tier 6.1_M1
K73001 updates SAS Customer Intelligence Logical Types 6.1_M1
K77001 updates SAS Customer Intelligence Processes 6.1_M1
K70001 updates SAS Customer Intelligence Reporting Mid-Tier 6.1_M1
K68001 updates SAS Customer Intelligence Studio 6.1_M1
K75001 updates SAS Customer Intelligence Utilities 6.1_M1
K76001 updates SAS Marketing Automation Extensions for SAS Customer Intelligence Studio 6.1_M1
K71001 updates SAS Marketing Automation Integration Utilities for MA 6.1_M1
Before applying this hot fix, follow the instructions in SAS Note 35968 to
generate a SAS Deployment Registry report, then verify that the appropriate product releases are installed on your system. The
release number information in the Registry report should match the 'member' release number information provided above for the
software components installed on each machine in your deployment.
The hot fix downloaded, K78001pt.zip, includes the updates required for all components listed above on all applicable operating systems. To apply this hot fix on multiple machines, you can either save K78001pt.zip on each machine or save it in a network location that is accessible to all machines.
Do NOT extract the contents of K78001pt.zip. The hot fix installation process will extract the contents as needed.
The hot fix will be applied using the SAS Deployment Manager (SDM). By default, the SDM will search in the <SASHOME>\InstallMisc\HotFixes\New directory for hot fixes to be applied, but will also prompt for a location if you have downloaded hot fixes to a different directory.
After downloading K78001pt.zip, follow the instructions for applying hot fixes in the SAS Deployment Wizard and SAS Deployment Manager 9.3: User’s Guide.
The hot fix installation process generates the log file
<!SASHOME>\InstallMisc\InstallLogs\IT_date-and-time-stamp.logfor example, IT_2011-10-31-13.18.21.log. Each attempt to apply a hot fix results in the creation of a new log file giving detailed information regarding the installation process.
Postexec log files are created after the installation is completed and identifies the files that were added, backed up, changed and removed. These log files include the ‘member’ hot fix id in the name of the file and are also written to the <!SASHOME>\InstallMisc\InstallLogs directory. There is one postexec log for each ‘member’ hot fix applied (member hot fixes are listed at the top of these instructions).
The content of this hot fix is listed in the hot fix manifest.
For example: copy_files.bat D:\SAS\Config\Lev1After running the copy_files.bat file please review the cictudio_hf.log for errors. The log can be found in the <CONFIGDIR>\Lev1\Logs folder.
K72001 updates Marketing Automation Launcher 6.1_M1
K67001 updates SAS Customer Intelligence Common Logical Types 6.1_M1
K79001 updates SAS Customer Intelligence Core Mid-Tier 6.1_M1
K73001 updates SAS Customer Intelligence Logical Types 6.1_M1
K77001 updates SAS Customer Intelligence Processes 6.1_M1
K70001 updates SAS Customer Intelligence Reporting Mid-Tier 6.1_M1
K68001 updates SAS Customer Intelligence Studio 6.1_M1
K75001 updates SAS Customer Intelligence Utilities 6.1_M1
K76001 updates SAS Marketing Automation Extensions for SAS Customer Intelligence Studio 6.1_M1
K71001 updates SAS Marketing Automation Integration Utilities for MA 6.1_M1
K72001 updates Marketing Automation Launcher 6.1_M1
NONE
K67001 updates SAS Customer Intelligence Common Logical Types 6.1_M1
NONE
K79001 updates SAS Customer Intelligence Core Mid-Tier 6.1_M1
Step 1: Re-build Web Applications
In order for this step to execute correctly, the Metadata Server must be running.
1.1 Invoke the SAS Deployment Manager 9.3
From the SASDeploymentManager directory launch sasdm.exe. The default installation path for the SAS Deployment Manager is
C:\Program Files\SASHome\SASDeploymentManager\9.3
1.2 Select a language in the Choose Language box
1.3 Select Rebuild Web Applications
1.4 Select Configuration Directory or Enter the Configuration Directory and Level that needs to be updated
1.5 Specify Connection Information, including the sasadm User ID and Password
1.6 Select Customer Intelligence Core Mid-Tier as the Web Application to Rebuild
1.7 Verify the information on the Summary screen and select Start
1.8 Select Finish when the deployment is complete
This process will update the Customer Intelligence Core ear in <CONFIGDIR>\Lev1\Web\Staging.
A backup of the original ear file will be placed in the Backup directory.
Step 2: Re-deploy Web Applications
2.1 Re-deploy the updated ear listed above to the web application server you are using based on the instructions appropriate for your web application server. See SAS 9.3 Intelligence Platform, Middle-Tier Administration Guide, Chapter 7, Administering SAS Web Applications, for more details.
K73001 updates SAS Customer Intelligence Logical Types 6.1_M1
You must reconfigure and restart SAS Remote Services SPECIFICALLY through the following steps so that the changes in SAS Customer Intelligence are surfaced. These steps ensure proper picklist regeneration for the product.
And change it to:
set SERVERTYPE=scripts
And change it to:
set SERVERTYPE=services
You may receive warning messages similar to the following:
WARNING: request for HIGHER version of <jar file name> ignored
These warnings are the result of newer platform files being referenced in the hot fix installation and do not compromise the functionality delivered.
K77001 updates SAS Customer Intelligence Processes 6.1_M1
NONE
K70001 updates SAS Customer Intelligence Reporting Mid-Tier 6.1_M1
Step 1: Re-build Web Applications
In order for this step to execute correctly, the Metadata Server must be running.
1.1 Invoke the SAS Deployment Manager 9.3
From the SASDeploymentManager directory launch sasdm.exe. The default installation path for the SAS Deployment Manager is
C:\Program Files\SASHome\SASDeploymentManager\9.3
1.2 Select a language in the Choose Language box
1.3 Select Rebuild Web Applications
1.4 Select Configuration Directory or Enter the Configuration Directory and Level that needs to be updated
1.5 Specify Connection Information, including the sasadm User ID and Password
1.6 Select Customer Intelligence Reporting Mid-Tier as the Web Application to Rebuild
1.7 Verify the information on the Summary screen and select Start
1.8 Select Finish when the deployment is complete
This process will update the Customer Intelligence Reporting Mid-Tier ear in <CONFIGDIR>\Lev1\Web\Staging.
A backup of the original ear file will be placed in the Backup directory.
Step 2: Re-deploy Web Applications
2.1 Re-deploy the updated ear listed above to the web application server you are using based on the instructions appropriate for your web application server. See SAS 9.3 Intelligence Platform, Middle-Tier Administration Guide, Chapter 7, Administering SAS Web Applications, for more details.
K68001 updates SAS Customer Intelligence Studio 6.1_M1
NONE
K75001 updates SAS Customer Intelligence Utilities 6.1_M1
NONE
K76001 updates SAS Marketing Automation Extensions for SAS Customer Intelligence Studio 6.1_M1
Step 1: Re-build Web Applications
In order for this step to execute correctly, the Metadata Server must be running.
1.1 Invoke the SAS Deployment Manager 9.3
From the SASDeploymentManager directory launch sasdm.exe. The default installation path for the SAS Deployment Manager is
C:\Program Files\SASHome\SASDeploymentManager\9.3
1.2 Select a language in the Choose Language box
1.3 Select Rebuild Web Applications
1.4 Select Configuration Directory or Enter the Configuration Directory and Level that needs to be updated
1.5 Specify Connection Information, including the sasadm User ID and Password
1.6 Select Customer Intelligence Studio as the Web Application to Rebuild
1.7 Verify the information on the Summary screen and select Start
1.8 Select Finish when the deployment is complete
This process will update the Customer Intelligence Studio ear in <CONFIGDIR>\Lev1\Web\Staging.
A backup of the original ear file will be placed in the Backup directory.
Step 2: Re-deploy Web Applications
2.1 Re-deploy the updated ear listed above to the web application server you are using based on the instructions appropriate for your web application server. See SAS 9.3 Intelligence Platform, Middle-Tier Administration Guide, Chapter 7, Administering SAS Web Applications, for more details.
K71001 updates SAS Marketing Automation Integration Utilities for MA 6.1_M1
NONE
This completes the installation of hot fix K78001 on Windows for x64.