>>>>>>>> SAS Notes -- Copyright (c) 1991 - 1999 by SAS Institute Inc. <<<<<<<<
V6-X11-G467 *** ALERT NOTE *** PRODUCT: ETS
TITLE: Tables in OUT= data set are incorrect with missing variable on VAR stmt
KEYS: TABLES OUT= DATA INCORRECT MISSING VARIABLE VAR STMT ARIMA INCORROUT
SHIFTED
If a variable with missing values for all observations is included on
a data set that is processed by PROC X11, and the "missing" variable
is included on the VAR statement, and the ARIMA statement is
specified, then the values for all of the tables output to the OUT=
data set are incorrect for all of the variables listed on the VAR
statement after the "missing" variable.
The table values shown in PROC X11's printed output are correct.
Only the values in the OUT= data set are incorrect. To circumvent
the problem, remove the variable with all missing values from the
VAR statement.
+------REPORTED------+ +---FIXED---+
SYSTEM RELEASE LEVEL RELEASE LEVEL
Apollo 6.07 TS101
AIX/R 6.07 TS101
AViiON 6.07 TS101
BULL 6.07 TS201
CMS 6.07 TS301
HP300 6.07 TS101
HP800 6.07 TS201
MIPS 6.07 TS101
MVS 6.07 TS301
NeXT 6.07 TS201
SGI 6.07 TS201
Siemens 6.07 TS201
Sun-3 6.07 TS201
Sun-4 6.07 TS201
ULTRIX 6.07 TS101
VMS 6.07 TS301
CMS 6.08 TS404
MVS 6.08 TS404
OS/2 6.08 TS404
VMS 6.08 TS404
VSE 6.08 TS404
Windows 6.08 TS404
CMS 6.09 TS450
MVS 6.09 TS450
VMS 6.09 TS450
IABI 6.10 TS018
MIPS ABI 6.10 TS018
Macintosh 6.10 TS037
OSF/AXP 6.10 TS018
OS/2 6.10 TS019
Windows 6.10 TS019
AIX/R 6.11 TS020
HP800 6.11 TS020
IABI 6.11 TS040
MIPS ABI 6.11 TS040
OSF/AXP 6.11 TS040
OS/2 6.11 TS020
Solaris 6.11 TS020
Windows 6.11 TS020
WIN/NT 6.11 TS040
Win95 6.11 TS040
AIX/R 6.12 TS020
DigitUnx 6.12 TS040
HP800 6.12 TS020
Macintosh 6.12 TS040
OS/2 6.12 TS020
Solaris 6.12 TS020
VMS/AXP 6.12 TS020
Windows 6.12 TS020
WIN/NT 6.12 TS020
Win95 6.12 TS020
This archive was generated by hypermail 2b29 : Mon Jan 10 2000 - 10:10:20 EST